Proper openings - enclosures (applicable to Zones A, A1-A30, AE, AO, AH, AR and AR dual)

Term · Insurance and risk management · MLC-T-INS-000194

All enclosures below the lowest elevated floor must be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. A minimum of 2 openings, with positioning on at least 2 walls, having a total net area of not less than 1 square inch for every square foot of enclosed area subject to flooding must be provided. The bottom of all openings must be no higher than 1 foot above the higher of the exterior or interior (adjacent) or floor immediately below the openings.