Batch Process Vent
Term · Environment · MLC-T-ENV-002865
1. Process vent with annual organic HAP emissions greater than 225 kilograms per year from a batch unit operation within an affected source. Annual organic HAP emissions are determined as specified in § 63.1323(b) at the location specified in § 63.1323(a)(2).
2. Process vent from a batch unit operation within an affected source. Batch process vents are either reactor batch process vents or non-reactor batch process vents.
3. Vent from a batch operation from a PVCPU through which a HAP-containing gas stream has the potential to be released to the atmosphere except that it is required by this subpart to routed to a closed vent system and control device. Emissions for all emission episodes associated with the unit operation(s) are part of the batch process vent. Batch process vents also include vents with intermittent flow from continuous operations. Examples of batch process vents include, but are not limited to, vents on condensers used for product recovery, polymerization reactors, and process tanks.
4. Vent from a CMPU or vents from multiple CMPUs within a process that are manifolded together into a common header, through which a HAP-containing gas stream is, or has the potential to be, released to the atmosphere. Batch process vents include vents from batch operations and vents with intermittent flow from continuous operations that are not combined with any stream that originated as a continuous gas stream from the same continuousprocess. Examples of batch process vents include, but are not limited to, vents on condensers used for product recovery, reactors, filters, centrifuges, and process tanks. The following are not batch process vents for the purposes of this subpart:(1) Continuous process vents;(2) Bottoms receivers;(3) Surge control vessels;(4) Gaseous streams routed to a fuel gas system(s);(5) A gas stream routed to other processes for reaction or other use in another process (i.e., for chemical value as a product, isolated intermediate, byproduct, or coproduct, or for heat value).(6) Vents on storage tanks or wastewater systems;(7) Drums, pails, and totes; and(8) Emission streams from emission episodes that are undiluted and uncontrolled containing less than 50 ppmv HAP are not part of any batch process vent. The HAP concentration may be determined using any of the following: process knowledge, an engineering assessment, or test data.
5. Gaseous streams routed to a fuel gas system(s) unless on and after August 12, 2023, the fuel gas system(s) supplies a flare of which 50 percent or more of the fuel gas burned in the flare is derived from an MCPU that has processes and/or equipment in ethylene oxide service, or produces olefins or polyolefins (8) Except for batch process vents in ethylene oxide service, emission streams from emission episodes that are undiluted and uncontrolled containing less than 50 ppmv HAP are not part of any batch process vent.
6. Gaseous venting to the atmosphere from a batch operation.
| Identifier | MLC-T-ENV-002865 |
|---|---|
| Field | Environment |
| References | 40 CFR 63.1312 (CFR 2013); 40 CFR 63.1402 (CFR (CFR 2013); 40 CFR 63.12005 (CFR 2013); 40 CFR 63.11502 (CFR (CFR 2013); Definition truncated. For full definition, see 85 FR 49084; 40 CFR 63.255 (CFR 2021); 40 CFR 63.101 (CFR 2024) |
Record as JSON
{
"id": "MLC-T-ENV-002865",
"term": "Batch Process Vent",
"field": "Environment",
"definition": "1. Process vent with annual organic HAP emissions greater than 225 kilograms per year from a batch unit operation within an affected source. Annual organic HAP emissions are determined as specified in § 63.1323(b) at the location specified in § 63.1323(a)(2).\n\n2. Process vent from a batch unit operation within an affected source. Batch process vents are either reactor batch process vents or non-reactor batch process vents.\n\n3. Vent from a batch operation from a PVCPU through which a HAP-containing gas stream has the potential to be released to the atmosphere except that it is required by this subpart to routed to a closed vent system and control device. Emissions for all emission episodes associated with the unit operation(s) are part of the batch process vent. Batch process vents also include vents with intermittent flow from continuous operations. Examples of batch process vents include, but are not limited to, vents on condensers used for product recovery, polymerization reactors, and process tanks.\n\n4. Vent from a CMPU or vents from multiple CMPUs within a process that are manifolded together into a common header, through which a HAP-containing gas stream is, or has the potential to be, released to the atmosphere. Batch process vents include vents from batch operations and vents with intermittent flow from continuous operations that are not combined with any stream that originated as a continuous gas stream from the same continuousprocess. Examples of batch process vents include, but are not limited to, vents on condensers used for product recovery, reactors, filters, centrifuges, and process tanks. The following are not batch process vents for the purposes of this subpart:(1) Continuous process vents;(2) Bottoms receivers;(3) Surge control vessels;(4) Gaseous streams routed to a fuel gas system(s);(5) A gas stream routed to other processes for reaction or other use in another process (i.e., for chemical value as a product, isolated intermediate, byproduct, or coproduct, or for heat value).(6) Vents on storage tanks or wastewater systems;(7) Drums, pails, and totes; and(8) Emission streams from emission episodes that are undiluted and uncontrolled containing less than 50 ppmv HAP are not part of any batch process vent. The HAP concentration may be determined using any of the following: process knowledge, an engineering assessment, or test data.\n\n5. Gaseous streams routed to a fuel gas system(s) unless on and after August 12, 2023, the fuel gas system(s) supplies a flare of which 50 percent or more of the fuel gas burned in the flare is derived from an MCPU that has processes and/or equipment in ethylene oxide service, or produces olefins or polyolefins (8) Except for batch process vents in ethylene oxide service, emission streams from emission episodes that are undiluted and uncontrolled containing less than 50 ppmv HAP are not part of any batch process vent.\n\n6. Gaseous venting to the atmosphere from a batch operation.",
"references": [
"40 CFR 63.1312 (CFR 2013)",
"40 CFR 63.1402 (CFR (CFR 2013)",
"40 CFR 63.12005 (CFR 2013)",
"40 CFR 63.11502 (CFR (CFR 2013)",
"Definition truncated. For full definition, see 85 FR 49084; 40 CFR 63.255 (CFR 2021)",
"40 CFR 63.101 (CFR 2024)"
],
"url": "https://mlchart.com/terminology/environment/batch-process-vent/"
}
Record 2,865 of 30,736 in Environment terminology (MLC-0121). Request the full dataset.