Maximum design waste burning capacity
Term · Environment · MLC-T-ENV-016738
1. For intermittent and continuous HMIWI, C=PV × 15,000/8,500Where:C=HMIWI capacity, lb/hrPV=primary chamber volume, ft3 15,000=primary chamber heat release rate factor, Btu/ft3/hr8,500=standard waste heating value, Btu/lb;(2) For batch HMIWI, C=PV × 4.5/8Where:C=HMIWI capacity, lb/hrPV=primary chamber volume, ft3 4.5=waste density, lb/ft3 8=typical hours of operation of a batch HMIWI, hours.
2. For intermittent and continuous HMIWI, see 9 493 for 2 definitions with equations included
| Identifier | MLC-T-ENV-016738 |
|---|---|
| Field | Environment |
| Subject | Regulatory activities |
| References | 40 CFR 60.51c (CFR 2013); 40 CFR 62.14490 (CFR 2018) |
Record as JSON
{
"id": "MLC-T-ENV-016738",
"term": "Maximum design waste burning capacity",
"field": "Environment",
"term_source": "Maximum Design Waste Burning Capacity",
"definition": "1. For intermittent and continuous HMIWI, C=PV × 15,000/8,500Where:C=HMIWI capacity, lb/hrPV=primary chamber volume, ft3 15,000=primary chamber heat release rate factor, Btu/ft3/hr8,500=standard waste heating value, Btu/lb;(2) For batch HMIWI, C=PV × 4.5/8Where:C=HMIWI capacity, lb/hrPV=primary chamber volume, ft3 4.5=waste density, lb/ft3 8=typical hours of operation of a batch HMIWI, hours.\n\n2. For intermittent and continuous HMIWI, see 9 493 for 2 definitions with equations included",
"subject": "Regulatory activities",
"references": [
"40 CFR 60.51c (CFR 2013)",
"40 CFR 62.14490 (CFR 2018)"
],
"url": "https://mlchart.com/terminology/environment/maximum-design-waste-burning-capacity/"
}