Analyte transport rate

Term · Chemistry · MLC-T-CHM-000548

The mass of analyte delivered to the plasma in each unit of time in atomic spectrometry with liquid sample introduction. It equals the analyte concentration multiplied by the sample uptake rate and by the fraction of the nebulized sample that survives transport through the spray chamber, so it is a mass flow rather than a velocity.

Table 1. Record
IdentifierMLC-T-CHM-000548
FieldChemistry
SubjectAnalytical Chemistry
ReferencesPAC, 2021, 93, 647. 'Glossary of methods and terms used in analytical spectroscopy (IUPAC Recommendations 2019)' on page 712 (https://doi.org/10.1515/pac-2019-0203)
Record as JSON
{
  "id": "MLC-T-CHM-000548",
  "term": "Analyte transport rate",
  "field": "Chemistry",
  "definition": "The mass of analyte delivered to the plasma in each unit of time in atomic spectrometry with liquid sample introduction. It equals the analyte concentration multiplied by the sample uptake rate and by the fraction of the nebulized sample that survives transport through the spray chamber, so it is a mass flow rather than a velocity.",